Error Analysis Lab

Error Analysis Lab By: Lab Team 5 Introduction and Background: In the process of learning about the importance of measurement and data processing, lab teams were given prompts to design experiments as well as address the precision, accuracy, and error analysis within the experiment. Lab teams collaborated their data to find similarities and differences within their measurements. Through this process, students learned the importance of the amount of uncertainty as well as the different types of experimental errors that might have caused a margin of difference within the lab teams results.

Measurement and data processing is a topic discussed in IB Chemistry SL; it is important within the scientific community as it discusses the reliability of the data presented. Uncertainty is used to determine a range of a value in a measurement or instrument. Uncertainty of an analogue instrument is plus or minus half of the smallest division present; while uncertainty of a digital scale is plus or minus the smallest division present. To identify the amount of uncertainty, significant figures (the digits in measurement up to and including the first uncertain digit) are used.

Certain rules are used to discover the number of significant figures in a value: * 1-9 are always significant * included zeroes (1009= 4 significant figures) * leading zeroes never count (0. 023= 2 significant figures) * trailing zeroes after the decimal count (1. 9850= 5 significant figures) Experimental errors are the difference between recorded value and generally accepted or literature value. There are two types of experimental errors: random and systematic errors. Random errors are caused by the readability of a measuring instrument, the effects of changes in the surroundings, insufficient data, and observer misinterpretation.

Systematic errors are errors that can not be reduced by repeating experiments or careful experimental design. These errors are caused by poor experimental design as well as improper measurement techniques. Accuracy is the difference between the experimental value and the accepted value. The greater the accuracy, the smaller the systematic error. Precision is the reproducibility of the experimental value. The greater precision, the less the random uncertainties. Purpose: Design laboratories based upon ideas of accuracy, precision and error analysis through creating a procedure and addressing the prompts.

Materials: * 13. 5 cm x 10 cm sheet of aluminum foil * Ruler * Balance * Laptop * Micrometer * Silver Cube of Unknown Solid * H2O (via sink) * Timer * Thermometer (in degrees Celsius) * 500 sheets of paper * Caliper * 100 mL graduated cylinder * 10 mL graduated cylinder * 25 mL flask Procedures and Methodologies: Station One (find volume, mass, and density of an unknown cube): 1 Find the height of the silver cube of unknown solid using the micrometer. 2 Find the length of the silver cube of unknown solid using the micrometer. 3 Find the width of the silver cube of unknown solid using the micrometer. Find the mass of the silver cube of unknown solid using the balance. 5 Using the measured length, width and height of the cube of unknown solid, calculate the volume of the cube. 6 Divide the mass of the cube by the volume to find the density of the cube. 7 Using the laptop, identify the type of metal based on the density. Station Two (find a way to measure 10. 5mL of water): 1 Using the 10 mL graduated cylinder, measure out 10 mL of water. 2 Pour the measured water into the 100 mL graduated cylinder. 3 Using the 10 mL graduated cylinder, measure 0. 5 mL of water. Pour the measured water into the 100 mL graduated cylinder, combining with the previously measured 10 mL of water. Station Three (measure the thickness of single sheet of paper and volume of 500 sheets): 1 Measure the height of the stack of paper with the ruler in millimeters (mm). 2 Measure the length of the stack of paper with the ruler in mm. 3 Measure the width of the stack of paper with the ruler in mm. 4 Calculate the volume of the stack of paper using the ruler’s dimensions in millimeters. 5 Calculate the thickness of one sheet of paper based on the ruler’s dimensions. Divide the height by number of sheets of paper [500 sheets]). 6 Repeat steps 1-5, instead using the caliper for measurements, but still measuring in millimeters. Station Four (calculate the volume of metal cylinder): 1 Using the caliper, measure the height of the cylinder in millimeters. 2 Using the caliper, measure the diameter of the cylinder’s circle in millimeters. 3 Using the volume of a cylinder formula (pi x radius squared x height), calculate the volume of the cylinder. Station Five (Calculate the thickness of aluminum foil): 1 Using a laptop, determine the accepted density for aluminum. Using the electronic balance, measure the mass of the sheet of aluminum foil. 3 Divide the mass by the accepted density to determine the volume. 4 Using the ruler, measure the dimensions (length x width) of the sheet of aluminium. 5 Divide the volume by the dimensions of the aluminum to determine the thickness. Station Six (Measure the temperature of the sink water for 120 seconds): 1 Turn hot water knob on. 2 Hold thermometer under running water. 3 Record temperature at 60 seconds. 4 Record temperature at 90 seconds. 5 Record temperature at 120 seconds. 6 Remove thermometer from water.

Station Seven (Determine the circumference, density, and identity of wire): 1 Using the micrometer, find the diameter of the of the wire 2 Multiply the diameter by pi (3. 14) to find the circumference of the wire 3 Using the ruler, find the length of the wire 4 Using the balance, find the mass of the wire 5 Multiply the circumference and the height of the wire to determine the volume 6 Divide mass by volume, to determine the density of the wire. 7 Using the laptop, identify the type of metal based on the density Data Collection: Station One- The results from measuring the volume, mass, and density of a unknown cube .

Using the density, the lab teams were able to identify the unknown cube. Group| Data| 1| volume=530 +- . 15mm3, mass= 7. 1+-. 05g, density=0. 12+-. 011gmm-3, lead| 2| volume=653+-. 01mm3, mass=7. 1+-. 1g, density=0. 01gmm-3, lead| 3| volume=580+-100mm3, mass 7. 14+-0. 001g, density= 0. 012gmm-3, lead| 4| volume=748+-0. 005mm3, mass= 7. 13g, density=0. 0009gmm-3, lead| 5| volume=727+-1mm3, mass=7. 14+-. 01g, density= . 01gmm-3, lead| 6| volume=621+-0. 05mm3, mass= 7. 15+-0. 01g, density=0. 0115gmm-3, lead| Station Two- Using the different graduated cylinders, lab teams measured out 10. 5 mL of water. Group| Data| 1| 10. +-. 5mL| 2| 10. 5+-. 1mL| 3| 10. 5+-. 05mL| 4| 10. 5+-. 5mL| 5| 10. 5+-. 5mL| 6| 10. 5+-. 5mL| Station Three- Provided with a ruler and micrometer, teams found the thickness of a single sheet of paper and the volume of 500 sheets of paper. Group| Data| 1| thickness=0. 01cm, volume=2950cm3| 2| thickness=0. 01cm, volume=6. 0cm3| 3| thickness=0. 01cm, volume=3100cm3| 4| thickness=0. 0096cm, volume= 2900cm3| 5| thickness= 0. 01cm, volume= 3100cm3| 6| thickness= 0. 0098cm, volume=2950cm3| Station Four- Given a metal caliper, students were asked to find the volume of a cylinder. Group| Data| 1| volume= 39+-2cm3| 2| volume= 38. +-2cm3| 3| volume= 63+-4. 9cm3| 4| volume=39+-2 cm3| 5| volume=41+- 1cm3| 6| volume= 38. 8+-. 1cm3| Station Five- Students calculated the thickness of a piece of aluminum foil using a balance and ruler. Group| Data| 1| 0. 0018+-0. 0002cm| 2| 0. 01646+-0. 0002cm| 3| 0. 0017+-0. 00002cm| 4| 0. 0022+-0. 00005cm| 5| 0. 00175+-0. 00005cm| 6| 0. 0018cm| Station Six- Lab teams measured the temperature of sink water over 120 seconds. Group| Data| 1| Start= 23+-. 5C, 60=22+-. 5C, 90=22+-. 5C, 120=22. 5C| 2| Start=21. 0+-. 5C, 60=21. 2+-. 5C, 90=21. 5+-. 5C, 120=21. 7+-. 5C| 3| 60=21+-. 5C, 90=22+-. 5C, 120=23+-. 5C| 4| 23+-. 5C| | 60=29C+-. 5, 90=29+-. 5C, 120=29+-. 5C| 6| Start= 21. 5C, 60= 22C, 90= 22. 25C, 120= 22. 5C| Station Seven- Using a micrometer, balance, and ruler, groups were asked to calculate the circumference, density and discover the identity of a wire. Group| Data| 1| circumference=6. 3+-+. 5mm, identity= copper, density= 0. 0033gmm-3| 2| circumference= 1. 19pi mm, identity= copper, density= 0. 011gmm-3| 3| circumference= 3. 14mm, identity= copper, density= 0. 13gmm-3| 4| circumference= 3. 93mm| 5| circumference= 3. 14 mm, identity= copper, density= 0. 13gmm-3| 6| circumference= 1. 23pi mm, identity= copper, density= 0. 307gcm-3|

Error Analysis: Station 1 (find volume, mass, and density of an unknown cube) In this particular station, there are no identified outliers. While the mass and density were rather close in value, there was no close range in the measurement of the volume of the unknown cube. This can be seen in the graphs below. Some random errors that may have caused this lack of precision in finding the volume of the unknown cube are misreadings of the instruments, changes in the environment of the experiment, the number of significant figures used, and the experimenter approximating a reading. Station 2 (find a way to measure 10. 5mL of water)

In this station, there were two identifies outliers. This included Group 2 and Group 3. They were identified as outliers because of the amount of uncertainty. This two groups had a rather small amount of uncertainty unlike the other four groups with identical amounts of uncertainty. This can be seen in the graph below. The error that would have caused the amount of uncertainty is systematic because water will have clinged to the sides of the graduated cylinder as it was emptying. Another reason it was a systematic error was the fact that too much water could have been added to the graduated cylinder as it was filled.

Station 3 There is only one large outlier within this station. In measuring the volume, Group 2 measured the volume to be 6. 0 cm3 while all other groups said the volume was around 3000cm3. This is such a huge gap that it would not be counted as a valuable measurement. Errors that could have occurred in this lab could have been random like the mismeasurement of the volume. The error could have also occurred by the misinterpretation of the question or prompt given. Station 4 The outlier in this station is group 3 with a Station 5 Station 6 Station 7

Conclusion and Evaluation: In result of the preformed lab, our team learned the importance of determining error as well as preventing the majority of this error. The large range of results most likely was a result of systematic error. This can be concluded because there were no set directions for each station, and a different procedure could have been used by each lab team. Another source of error can be seen in the difference in sig figs used between groups. Random error most likely was a result of the unfamiliar tools that were used for the first time by many students.

Calculate the price
Make an order in advance and get the best price
Pages (550 words)
$0.00
*Price with a welcome 15% discount applied.
Pro tip: If you want to save more money and pay the lowest price, you need to set a more extended deadline.
We know how difficult it is to be a student these days. That's why our prices are one of the most affordable on the market, and there are no hidden fees.

Instead, we offer bonuses, discounts, and free services to make your experience outstanding.
How it works
Receive a 100% original paper that will pass Turnitin from a top essay writing service
step 1
Upload your instructions
Fill out the order form and provide paper details. You can even attach screenshots or add additional instructions later. If something is not clear or missing, the writer will contact you for clarification.
Pro service tips
How to get the most out of your experience with MyStudyWriters
One writer throughout the entire course
If you like the writer, you can hire them again. Just copy & paste their ID on the order form ("Preferred Writer's ID" field). This way, your vocabulary will be uniform, and the writer will be aware of your needs.
The same paper from different writers
You can order essay or any other work from two different writers to choose the best one or give another version to a friend. This can be done through the add-on "Same paper from another writer."
Copy of sources used by the writer
Our college essay writers work with ScienceDirect and other databases. They can send you articles or materials used in PDF or through screenshots. Just tick the "Copy of sources" field on the order form.
Testimonials
See why 20k+ students have chosen us as their sole writing assistance provider
Check out the latest reviews and opinions submitted by real customers worldwide and make an informed decision.
Business and administrative studies
perfect
Customer 452773, February 23rd, 2023
Leadership Studies
excellent job
Customer 452773, August 26th, 2023
Nursing
I just need some minor alterations. Thanks.
Customer 452547, February 10th, 2021
Human Resources Management (HRM)
excellent work
Customer 452773, July 3rd, 2023
Business Studies
Thank you very much for a good job done and a quick turn around time.
Customer 452615, March 31st, 2021
Leadership Studies
awesome work as always
Customer 452773, August 19th, 2023
FIN571
excellent work
Customer 452773, March 1st, 2024
10th grade English
very good
Customer 452773, March 26th, 2023
Business and administrative studies
Excellent job
Customer 452773, March 17th, 2023
Human Resources Management (HRM)
excellent job
Customer 452773, June 25th, 2023
LEADERSHIP
excellent job
Customer 452773, August 12th, 2023
Leadership Studies
excellent job
Customer 452773, July 28th, 2023
11,595
Customer reviews in total
96%
Current satisfaction rate
3 pages
Average paper length
37%
Customers referred by a friend
OUR GIFT TO YOU
15% OFF your first order
Use a coupon FIRST15 and enjoy expert help with any task at the most affordable price.
Claim my 15% OFF Order in Chat
Close

Sometimes it is hard to do all the work on your own

Let us help you get a good grade on your paper. Get professional help and free up your time for more important courses. Let us handle your;

  • Dissertations and Thesis
  • Essays
  • All Assignments

  • Research papers
  • Terms Papers
  • Online Classes
Live ChatWhatsApp